Call UsCall Us : 08045812579
Change Language

Integral Type With PTFE Liner Flow Meter

Integral Type With PTFE Liner Flow Meter

Product Details:

  • Color Blue
  • Size Standard
  • Material Stainless Steel
  • Power Supply 220 VAC or 24 VDC
  • Power Consumption 20 Watt (W)
  • Accuracy 0.5 %
  • Display Type Digital Only
22000 INR
X

Integral Type With PTFE Liner Flow Meter Price And Quantity

  • 1 Piece
  • 22000 INR

Integral Type With PTFE Liner Flow Meter Product Specifications

  • 220 VAC or 24 VDC
  • 0.5 %
  • Stainless Steel
  • Blue
  • Standard
  • 20 Watt (W)
  • Digital Only

Product Description

Electromagnetic Flow Meters are based on FARADAY'S LAW INDUCTION. These meters are also called as

Magflow or Electromagnetic Flow Meters. A magnetic field is applied to the metering tube, which results in a potential

difference proportional to the flow velocity perpendicular to the flux lines.

The physical principle at work is Electromagnetic Induction and mathematically defined as E=k*B*D*V.

where, E = Induced Voltage (Linear with velocity)

 K = Proportionality Constant

 B = Magnetic Field Strength (Coil Inductance)

 D = Distance between electrodes

 V = Velocity of process fluids

of a sensor and a converter that may be mounted integral to the sensor or remotely either with a field mount kit. 

Technical Specification 

Line Size

DN 25 - DN 3000 mm

Nominal Pressure

0.6 - 1.6 Mpa (2.5Mpa/4.0Mpa/6.4MpaMax 42Mpa)

Accuracy

+/-0.5%(Standard)

Liner

PTFE, Hard Rubber

Electrode

SS 316L, Hastelloy C, Tantalum

Type

Integral type, Remote type with 10 mtr. cable

Medium Temperature

-20+80 deg C (Integral type)

Remote type (Hard Rubber)

-10+80degC

Remote type (PTFE)

-10+160degC

Ambient Humidity

5-100%RH (relative humidity)

Conductivity

>15us/cm

Protection Class

IP65 (Standard); IP68 (Optional for remote type)

Process Connection

Flange (Standard), Wafer, Thread, Tri-clamp etc (Optional)

Output Signal

4-20mA (Standard) / Pulse (Optional)

Communication

RS485(Standard),GPRS/GSM (Optional)

Power Supply

Integral - 24 V DC , AC 220V

Remote - 24 V DC (Standard) , SMPS AC 220V (Optional)

Power Consumption

20W

 Main Performances of the Electrode Materials

Electrode Material

Application

SS 316L

Applicable in Water, Sewage and Low corrosive medium

Hastelloy C

Be resistant to oxidable acid such as nitric acid, mixed acid as well as

oxidable salt such as Fe+++,Cu++ and sea water

Tantalum

Having strong resistance to corrosive mediums that is similar with glass.

Almost applicable in all chemicals mediums except for hydrofluoric acid,

oleum and alkali